Teleline – Mutual Drainage Reactors

Standalone Mutual Drainage Reactor

The Standalone Mutual Drainage Reactor is designed to protect communications equipment against the high voltages which may be induced onto telephone pairs, within a telecommunication cable during power fault conditions.

The Mutual Drainage Reactor provides a direct drainage path to ground for common mode induced voltages while maintaining a high impedance to AC differential telephone signals (typically 60 to 4000 Hz). The result is safe, uninterruptible communication before, during, and after fault conditions (ideally used on class “A” circuits).

The Mutual Drainage Reactor

The Mutual Drainage Reactor is generally intended to be installed outside the zone of influence of high voltage environments, in Central Offices (COs), and field cabinets.

NOTE: Please note that the installation procedure from the installation guide has been updated.

PRODUCTCLEI CODEDESCRIPTION
751200PWUYACBMAAStandalone Mutual Drainage Reactor

Mutual Drainage Reactor Assembly Shelf

The Mutual Drainage Reactor Assembly is intended to replace the standalone drainage reactor used primarily in the Central Office (CO) of a telephone company. The Mutual Drainage Reactor Assembly is comprised of a module (Model 751300) and a shelf (Model 751201).

As a modular, plug-in arrangement, this system offers a neat and organized installation in a CO.

The Mutual Drainage Reactor shelf

The Mutual Drainage Reactor shelf, Model 751201, is a 23”x 5-1/4”, baymount shelf which accommodates up to eight plug-in Mutual Drainage Reactor modules. The shelf is equipped with a smoked Lexan non-hinged door for aesthetics.

The Mutual Drainage Reactor Assembly provides a direct drainage path to ground for common mode induced voltages while maintaining a high impedance to AC differential telephone signals (typically 60 to 4000 Hz). The result is safe, uninterruptible communication before, during, and after fault conditions. It is ideally used on class “A” circuits.

NOTE: Please note that the installation procedure from the installation guide has been updated.

PRODUCTCLEI CODEDESCRIPTIONDOWNLOAD
751201NPMWR002RAMutual Drainage Reactor Assembly ShelfUser guide

Mutual Drainage Reactor Module

The Mutual Drainage Reactor Assembly is intended to replace the standalone drainage reactor used primarily in the Central Office (CO) of a telephone company. The Mutual Drainage Reactor Assembly is comprised of a module (Model 751300) and a shelf (Model 751201).

As a modular, plug-in arrangement, this system offers a neat and organized installation in a CO.

The Mutual Drainage Reactor module

The Mutual Drainage Reactor module, Model 751300, is designed to protect communications equipment against the high voltages which may be induced onto telephone pairs, within a telecommunication cable, during power fault conditions.

The Mutual Drainage Reactor Assembly provides a direct drainage path to ground for common mode induced voltages while maintaining a high impedance to AC differential telephone signals (typically 60 to 4000 Hz). The result is safe, uninterruptible communication before, during, and after fault conditions. It is ideally used on class “A” circuits.

NOTE: Please note that the installation procedure from the installation guide has been updated.

PRODUCTCLEI CODEDESCRIPTIONDOWNLOAD
751300NPDT4002AAMutual Drainage Reactor ModuleUser guide